Product List

Application of the Product Database for Large Heat Pumps

To identify suitable units for your specific application, you can define various search criteria on this page. These allow you to identify the large heat pumps that are appropriate for your application and obtain detailed technical information.

Defining Search Criteria: To determine which large heat pumps are suitable for your project, you can adjust various filter options. These search criteria are listed in the left column of the webpage:

  • Maximum Flow Temperature: Enter the maximum flow temperature for your project.
  • Rated Heating Capacity: Filter by the heating capacity of the unit.
  • Refrigerant Category: Select the appropriate refrigerant category.
  • Source Type: Define what type of heat source is being used.
  • Circuit Type: Determine the type of circuit system.

Note: It is not necessary to fill out all search criteria – however, the more filters you set, the more specific your product selection will be.

Detailed View of Manufacturers and Products:

Click on a manufacturer's name to obtain extended information about them. When you click on a product name, a detailed view opens with all available information about that product.

Extended Information: For more detailed information on the various refrigerants, heat sources, and circuit types, infobuttons are available. By clicking on these buttons, you will receive a brief overview of each term.

Database Analysis and API Access: If you wish to conduct an independent evaluation of the database, you can access the database under the menu item Product API . The database is available to you as a JSON REST API.

For more information, click on a product or visit the page on a larger screen.

Manufacturer Product Source Type Refrigerant Circuit Type Thermal Capacity [kW] Flow Temperature [°C] Verified
Rhoss Deutschland GmbH / Rhoss S.p.a. FullFlow-I Booster ECO / FullFlow Brine/Water R1234ze(E), R515B (R1234ze(E)/ 227ea) Closed 400-1,000 85
Rhoss Deutschland GmbH / Rhoss S.p.a. WinPower ECO / WinPower Air R454B Closed 350-810 58
Rhoss Deutschland GmbH / Rhoss S.p.a. WinPower ECO Twin / WinPower Air R454B Closed 860-1,310 58
Siemens Energy SHP-C600/C750 / SHP-C600/C750 Brine/Water R1234ze(Z) Closed 15,000-45,000 150
Siemens Energy SHP-STC-XX W/S / SHP-STC-XX W/S Brine/Water R1234ze(Z) Closed 5,000-70,000 100
SKADEC GmbH SC.F. R290 / SC.F. Brine/Water R290 (Propan) Closed 400-3,200 65
SKADEC GmbH SH.C. R600 / SH.C. Air, Brine/Water R600a (Isobutan) Closed 60-400 30-90
SKADEC GmbH SH.D.F. 2 Kreisläufe / SH.D. Air R290 (Propan) Closed 230-310 30-65
SKADEC GmbH SH.D.F. 3 Kreisläufe / SH.D. Air R290 (Propan) Closed 310-465 30-65
SKADEC GmbH SH.D.F. 4 Kreisläufe / SH.D. Air R290 (Propan) Closed 465-620 30-65
SKADEC GmbH SH.F. R600 / SH.F. Air, Brine/Water R600a (Isobutan) Closed 400-2,200 30-90
SPH Sustainable Process Heat GmbH LL1 / ThermBooster Air, Brine/Water, Steam R1224yd(Z), R1233zd(E), R1234ze(Z), R1336mzz(Z), R515B (R1234ze(E)/ 227ea), R600 (Butan), R600a (Isobutan), R601 (Pentan), R601a (Isopentan) Closed 200-8,000 10-160
SPH Sustainable Process Heat GmbH LL1-2 / ThermBooster Air, Brine/Water, Steam R1224yd(Z), R1233zd(E), R1234ze(Z), R1336mzz(Z), R515B (R1234ze(E)/ 227ea), R600 (Butan), R600a (Isobutan), R601 (Pentan), R601a (Isopentan) Closed 200-8,000 10-160
SPH Sustainable Process Heat GmbH LL2 / ThermBooster Air, Brine/Water, Steam R1224yd(Z), R1233zd(E), R1234ze(Z), R1336mzz(Z), R515B (R1234ze(E)/ 227ea), R600 (Butan), R600a (Isobutan), R601 (Pentan), R601a (Isopentan) Closed 200-8,000 10-160
SPH Sustainable Process Heat GmbH LL2-2 / ThermBooster Air, Brine/Water, Steam R1224yd(Z), R1233zd(E), R1234ze(Z), R1336mzz(Z), R515B (R1234ze(E)/ 227ea), R600 (Butan), R600a (Isobutan), R601 (Pentan), R601a (Isopentan) Closed 200-8,000 10-160
SPH Sustainable Process Heat GmbH LL3 / ThermBooster Air, Brine/Water, Steam R1224yd(Z), R1233zd(E), R1234ze(Z), R1336mzz(Z), R515B (R1234ze(E)/ 227ea), R600 (Butan), R600a (Isobutan), R601 (Pentan), R601a (Isopentan) Closed 200-8,000 10-160
SPH Sustainable Process Heat GmbH LS1 / ThermBooster Air, Brine/Water, Steam R1224yd(Z), R1233zd(E), R1234ze(Z), R1336mzz(Z), R515B (R1234ze(E)/ 227ea), R600 (Butan), R600a (Isobutan), R601 (Pentan), R601a (Isopentan) Closed 200-8,000 10-160
SPH Sustainable Process Heat GmbH LS1-2 / ThermBooster Air, Brine/Water, Steam R1224yd(Z), R1233zd(E), R1234ze(Z), R1336mzz(Z), R515B (R1234ze(E)/ 227ea), R600 (Butan), R600a (Isobutan), R601 (Pentan), R601a (Isopentan) Closed 200-8,000 10-160
SPH Sustainable Process Heat GmbH LS2 / ThermBooster Air, Brine/Water, Steam R1224yd(Z), R1233zd(E), R1234ze(Z), R1336mzz(Z), R515B (R1234ze(E)/ 227ea), R600 (Butan), R600a (Isobutan), R601 (Pentan), R601a (Isopentan) Closed 200-8,000 10-160
SPH Sustainable Process Heat GmbH LS2-2 / ThermBooster Air, Brine/Water, Steam R1224yd(Z), R1233zd(E), R1234ze(Z), R1336mzz(Z), R515B (R1234ze(E)/ 227ea), R600 (Butan), R600a (Isobutan), R601 (Pentan), R601a (Isopentan) Closed 200-8,000 10-160